[Durgical](https://durgical.com/en/) › [DurgiPedia](https://durgical.com/en/durgipedia/) › [Anaesthesia and ICU](https://durgical.com/en/anaesthesia/) › [Critical care (ICU)](https://durgical.com/en/anaesthesia/areas/critical-care/) › Shock haemodynamic profiles: output, resistance, filling pressures and venous saturation

# Shock haemodynamic profiles: output, resistance, filling pressures and venous saturation

- Concept

Each type of shock moves four numbers in its own pattern. Read the pattern and you know which kind of shock it is and what to fix.

Updated Nov 15, 2026

## Key points

- Hypovolaemic: low output, high resistance, low filling pressures, low venous saturation.
- Cardiogenic ([left ventricle](https://durgical.com/en/anatomy/left-ventricle/)): low output, high resistance, high wedge pressure, low venous saturation.
- Obstructive: low output and high resistance; tamponade equalises the diastolic pressures, a massive [pulmonary embolism](https://durgical.com/en/conditions/pulmonary-embolism/) raises the central venous pressure with a low or normal wedge.
- Distributive (resuscitated sepsis): normal or high output, low resistance, low or normal filling pressures, normal or high venous saturation.
- The pulmonary artery catheter measures right-sided pressures, the wedge pressure, thermodilution output and mixed venous saturation; routine use did not improve survival.

On this page

- The basics Key points
- What it is
- How to think about it
- Key points
- Components
- Step by step
- In practice
- Next step
- Common traps
- Elsewhere in DurgiPedia

- Treatment The classic profiles (arrows show the usual direction before treatment changes them)

- Study Test yourself

- Connections Connections

## What it is

A haemodynamic profile is the set of measurements that describes a circulation: cardiac output (or cardiac index, output corrected for body size), systemic vascular resistance (the tone of the arterioles), the filling pressures (central venous pressure for the right heart, pulmonary capillary wedge pressure for the left) and mixed or central venous [oxygen](https://durgical.com/en/pharmacology/oxygen/) saturation (how much oxygen is left in blood returning to the heart). Every type of shock starts with one primary fault and the body answers with compensations, so each type has a recognisable pattern. [Hypovolaemic shock](https://durgical.com/en/conditions/hypovolaemic-shock/) starts with too little filling; [cardiogenic shock](https://durgical.com/en/conditions/cardiogenic-shock/) with a failing pump; obstructive shock with a block in the circuit (tamponade, tension [pneumothorax](https://durgical.com/en/conditions/pneumothorax/), massive pulmonary embolism); distributive shock with arterioles that have lost their tone (sepsis, [anaphylaxis](https://durgical.com/en/conditions/anaphylaxis/), [spinal cord injury](https://durgical.com/en/conditions/spinal-cord-injury/)). The pulmonary artery catheter measures all of these directly, but it is now used rarely because trials showed no survival benefit from routine use and it carries real risks; bedside echocardiography and less invasive output monitors answer the same questions in most patients.

## How to think about it

Find the one primary fault, then read the other numbers as the body's reply. Pressures pile up upstream of a failing pump or a block and fall downstream of it; resistance rises to defend [blood pressure](https://durgical.com/en/physiology/systolic-diastolic-mean-and-pulse-pressure/) whenever output falls; venous saturation falls whenever delivery cannot keep up with demand, except when the tissues cannot take oxygen out at all.

## Key points

- [Mean arterial pressure](https://durgical.com/en/nursing/icu-bedside-formulas-mean-arterial-pressure-cerebral-perfusion-pressure-cardiac/) ≈ cardiac output × systemic vascular resistance (plus central venous pressure): a normal pressure can hide a low output held up by vasoconstriction.
- The wedge pressure is the pressure measured when a balloon at the catheter tip occludes a branch of the pulmonary artery; it approximates left atrial pressure and so left ventricular filling.
- Mixed venous saturation is sampled from the pulmonary artery; central venous saturation from the [superior vena cava](https://durgical.com/en/anatomy/superior-vena-cava/) runs a little higher in health and is the usual bedside substitute.
- Normal values to anchor the patterns: cardiac index roughly 2.5–4 litres per minute per square metre, wedge pressure about 6–12 mmHg, central venous pressure about 2–8 mmHg, mixed venous saturation about 65–75%.
- Profiles describe a moment: treatment changes them, so septic shock before fluids can look hypovolaemic and septic cardiomyopathy can make it look cardiogenic.

## Components

- Pulmonary artery catheter: a balloon-tipped catheter floated from a central vein through the [right atrium](https://durgical.com/en/anatomy/right-atrium/) and [right ventricle](https://durgical.com/en/anatomy/right-ventricle/) into the pulmonary artery.
- Its lumens and sensors: a proximal port in the right atrium (central venous pressure), a distal port in the pulmonary artery (pulmonary pressures, wedge pressure, mixed venous blood) and a thermistor near the tip (thermodilution output).
- Derived values: systemic vascular resistance from mean arterial pressure, central venous pressure and output; [pulmonary vascular resistance](https://durgical.com/en/physiology/the-pulmonary-circulation-and-hypoxic-vasoconstriction/) from pulmonary pressures, wedge pressure and output.

## Step by step

- Is output low or high? Low output with cold skin means hypovolaemic, cardiogenic or obstructive; high output with warm skin points to distributive.
- If output is low, look at the filling pressures: low pressures mean an empty heart (hypovolaemia); high pressures mean the blood is backing up.
- If pressures are high, ask where: a high wedge points to the left ventricle; high right pressures with a low wedge, to the right heart or lung circulation.
- Equal right atrial, right ventricular diastolic, pulmonary diastolic and wedge pressures suggest tamponade: all four chambers are squeezed alike.
- Read resistance as the reply: it rises when output falls (the body defends pressure) and is low only when vessel tone itself has failed.
- Read venous saturation last: low means delivery is not keeping up; normal or high in shock means oxygen is not being extracted, as in sepsis.

## The classic profiles (arrows show the usual direction before treatment changes them)

| Shock type | Cardiac output | Vascular resistance | Wedge pressure | Central venous pressure | Venous saturation |
| --- | --- | --- | --- | --- | --- |
| Hypovolaemic | ↓ | ↑ | ↓ | ↓ | ↓ |
| Cardiogenic (left ventricle) | ↓ | ↑ | ↑ | ↑ or normal | ↓ |
| Obstructive: tamponade | ↓ | ↑ | ↑ (equal to the right-sided diastolic pressures) | ↑ | ↓ |
| Obstructive: massive pulmonary embolism | ↓ | ↑ | ↓ or normal | ↑ | ↓ |
| Distributive: septic, after fluids | ↑ or normal | ↓ | ↓ or normal | ↓ or normal | Normal or ↑ |
| Distributive: neurogenic | ↓ or normal (slow heart) | ↓ | ↓ | ↓ | Variable |

## In practice

- Most profiles are now read at the bedside without a catheter: skin temperature and capillary refill for output, neck veins and echocardiography for filling and ventricular function, [lactate](https://durgical.com/en/biochemistry/molecules/lactate/) and venous saturation for delivery.
- The pulmonary artery catheter is still used in selected patients: cardiogenic shock in specialised centres, [pulmonary hypertension](https://durgical.com/en/general-pathology/pulmonary-hypertension/), cardiac surgery and [heart transplant](https://durgical.com/en/conditions/advanced-heart-failure-transplant-and-lvad/) assessment.
- Its risks include arrhythmias while passing the right ventricle, pulmonary artery rupture or infarction, infection, thrombosis and knotting; wrong readings are more common than these.
- Mixed patterns are common: septic shock with septic cardiomyopathy, cardiogenic shock with a vasodilatory component after a large infarction, or haemorrhage in a patient with [heart failure](https://durgical.com/en/conditions/heart-failure/).

## Next step

- Classify shock first with the bedside picture, echocardiography, lactate and central venous saturation; a profile adds detail, not the first answer.
- Call the critical care or cardiology team when the type stays unclear or treatment fails; they decide whether invasive output monitoring is worth its risks.
- Re-read the profile after every major change (fluid, vasopressor, inotrope) because each treatment moves the numbers.
- Treat obstructive causes mechanically: drainage for tamponade and decompression for tension pneumothorax are not delayed for measurements.

## Common traps

- **Mistaken belief**: a normal or high venous saturation means the tissues are well supplied. Correction: in septic shock it can be high because tissues cannot extract oxygen or blood bypasses them; check lactate and the CO2 gap.
- **Mistaken belief**: obstructive shock is just a kind of cardiogenic shock. Correction: the muscle is healthy and the block decides the pressures; a pulmonary embolism raises right-sided pressures but leaves the wedge low.
- **Mistaken belief**: septic shock is always warm. Correction: before fluids it looks hypovolaemic, and septic cardiomyopathy can lower output; the profile follows the phase, not the label.
- **Mistaken belief**: the wedge pressure always equals left ventricular filling. Correction: [mitral stenosis](https://durgical.com/en/conditions/mitral-stenosis/), high intrathoracic pressure and a tip in the wrong lung zone all break the link.
- **Mistaken belief**: [neurogenic shock](https://durgical.com/en/conditions/neurogenic-shock/) is hypovolaemia after trauma. Correction: low resistance with a slow heart and warm skin; look for bleeding first, but suspect it in a spinal cord injury.

## Test yourself

Think of the answer, then tap the question to see it.

## Why does systemic vascular resistance rise in hypovolaemic and cardiogenic shock?

Output falls, so baroreflexes and hormones constrict arterioles to hold blood pressure up; the high resistance is the body's reply, not the primary fault.

## Which pressure pattern on a pulmonary artery catheter suggests cardiac tamponade?

Equalisation of diastolic pressures: right atrial, right ventricular diastolic, pulmonary artery diastolic and wedge pressures are all raised and nearly the same.

## A massive pulmonary embolism: why is central venous pressure high but the wedge pressure low?

The block sits between the right and left heart: blood backs up behind it into the right side, while the [left atrium](https://durgical.com/en/anatomy/left-atrium/) downstream receives too little.

## Why can venous oxygen saturation be high in septic shock while lactate rises?

Microcirculatory shunting and mitochondrial dysfunction stop tissues using the oxygen delivered, so venous blood returns oxygen-rich despite [tissue hypoxia](https://durgical.com/en/physiology/types-of-hypoxia-and-what-hypoxia-does-to-the-body/).

## Why is the pulmonary artery catheter rarely used today?

Trials found no survival benefit from routine use, it carries risks such as arrhythmia, rupture and infection, and echocardiography answers most of the same questions.

[Add to my cards (5)](https://durgical.app/estudiar/?add=/en/anaesthesia/shock-haemodynamic-profiles-output-resistance-filling-pressures-and-venous-satur/)

## Elsewhere in DurgiPedia

- [Shock physiology](https://durgical.com/en/physiology/shock-physiology/)
- [Measuring cardiac output: Fick, indicator and thermodilution, Doppler](https://durgical.com/en/physiology/measuring-cardiac-output-fick-indicator-and-thermodilution-doppler/)
- [Oxygen content, delivery and extraction](https://durgical.com/en/physiology/oxygen-content-delivery-and-extraction/)
- [Central venous pressure and the jugular pulse](https://durgical.com/en/physiology/central-venous-pressure-and-the-jugular-pulse/)
- [Shock: types, stages and the organs it damages](https://durgical.com/en/general-pathology/shock-types-stages-and-the-organs-it-damages/)

## Connections

## Related 5

- [Shock: a bedside approach by type](https://durgical.com/en/anaesthesia/shock-a-bedside-approach-by-type/)
- [Haemodynamic monitoring: arterial line, CVP, cardiac output and lactate](https://durgical.com/en/anaesthesia/haemodynamic-monitoring-arterial-line-cvp-cardiac-output-and-lactate/)
- [Fluid responsiveness: when more fluid helps](https://durgical.com/en/anaesthesia/fluid-responsiveness-when-more-fluid-helps/)
- [Vasopressors and inotropes by receptor and mechanism](https://durgical.com/en/anaesthesia/vasopressors-and-inotropes-by-receptor-and-mechanism/)
- [Central lines in the ICU: choice, checks and removal](https://durgical.com/en/anaesthesia/central-lines-in-the-icu-choice-checks-and-removal/)

## Related conditions 7

- [Hypovolaemic shock](https://durgical.com/en/conditions/hypovolaemic-shock/)
- [Cardiogenic shock](https://durgical.com/en/conditions/cardiogenic-shock/)
- [Sepsis and septic shock](https://durgical.com/en/conditions/sepsis-and-septic-shock/)
- [Cardiac tamponade](https://durgical.com/en/conditions/cardiac-tamponade/)
- [Pulmonary embolism](https://durgical.com/en/conditions/pulmonary-embolism/)
- [Neurogenic shock](https://durgical.com/en/conditions/neurogenic-shock/)
- [Anaphylaxis](https://durgical.com/en/conditions/anaphylaxis/)

[← All of anaesthesia](https://durgical.com/en/anaesthesia/)

Educational content; it does not replace supervised training, your institution's protocols or the anaesthetist's or intensivist's decision. It contains no doses and no ventilator or infusion settings.

Sources: [Shock](https://www.ncbi.nlm.nih.gov/books/NBK531492/) (StatPearls (NCBI Bookshelf), 2023); [Pulmonary Artery Catheterization](https://www.ncbi.nlm.nih.gov/books/NBK482170/) (StatPearls (NCBI Bookshelf), 2023); [Cardiogenic Shock](https://www.ncbi.nlm.nih.gov/books/NBK482255/) (StatPearls (NCBI Bookshelf), 2023); [Distributive Shock](https://www.ncbi.nlm.nih.gov/books/NBK470316/) (StatPearls (NCBI Bookshelf), 2023).

## **Spotted a mistake?** We are always improving for the community. Tell us what is wrong and our team will review it. Report a mistake

Representative model, for educational purposes only.

---
Source: https://durgical.com/en/anaesthesia/shock-haemodynamic-profiles-output-resistance-filling-pressures-and-venous-satur/
License: CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). Cite as: DurgiPedia (durgical.com), https://durgical.com/en/anaesthesia/shock-haemodynamic-profiles-output-resistance-filling-pressures-and-venous-satur/