[Durgical](https://durgical.com/en/) › [DurgiPedia](https://durgical.com/en/durgipedia/) › [Nursing](https://durgical.com/en/nursing/) › [Medical–surgical nursing](https://durgical.com/en/nursing/areas/med-surg/) › Patients with a pacemaker or ICD: care after implant, wound and arm care, device teaching

# Patients with a pacemaker or ICD: care after implant, wound and arm care, device teaching

- Safe practice

After a pacemaker or defibrillator implant, the nurse watches the rhythm and wound, limits the arm on that side, and teaches device safety and when to call.

Updated Nov 13, 2026

## Key points

- For several weeks the arm on the device side is not raised above the shoulder, and heavy lifting, pushing and pulling are avoided.
- Keep the wound dry for the first days as instructed; wash hands before touching it; report redness, swelling, drainage or pain.
- Persistent hiccups, dizziness, fainting, chest pain or the return of the old symptoms must be reported.
- Carry the device card; keep the mobile phone on the opposite side and magnets away from the device; show the card at security checks.
- Every ICD shock is reported to the cardiology team; the patient agrees in advance when a shock means calling the emergency line.

## What it is

A pacemaker treats a heart that beats too slowly; an implantable cardioverter-defibrillator (ICD) detects a dangerous fast rhythm and delivers a shock to stop it. After the implant the nurse watches the monitor, the wound and the vital signs, and helps the patient keep the arm on the device side low and still so the leads stay in place. Teaching covers wound care, arm and lifting limits for the first weeks, carrying the device card, keeping magnets and some equipment away from the device, check-ups, and what to do after an ICD shock.

## What it requires

- Rhythm monitoring after the implant and comparison with the expected device function.
- Wound care and early detection of bleeding, haematoma or infection.
- Protecting the leads: arm and lifting limits for the first weeks.
- Device teaching: card, magnets and equipment, phones, security checks, imaging tests and check-ups.
- Planning with the team what to do after an ICD shock.

## How it is applied (and why)

- Attach the cardiac monitor and watch the rhythm and heart rate as ordered — shows whether the device is working as expected.
- Measure vital signs and ask about dizziness, chest pain and breathlessness — these may mean a device or lead problem.
- Inspect the dressing and the pocket for bleeding, swelling or a haematoma — the pocket can bleed in the first hours.
- Help the patient keep the device-side arm low and avoid raising it above the shoulder — a new lead can move.
- Report persistent hiccups — they are one of the warning signs after a device implant.
- Teach wound care: keep it dry as instructed, hand hygiene, no creams, and the infection signs — the pocket can become infected.
- Teach the device card, magnets and equipment distances, phone side and security checks — strong fields can interfere.
- For an ICD, agree with the team on what to do after a shock and teach it to the family — the plan avoids panic.
- Confirm the check-up dates and that every provider is told about the device before tests — some tests need settings checked.

## In nursing practice

- Call for wound redness, swelling, more drainage, pain or fever.
- Call for dizziness, fainting, breathlessness, chest pain or a return of the symptoms the device was meant to treat.
- Call for persistent hiccups or a pulse well below the expected rate.
- After an ICD shock: report it; if the patient feels unwell, faints or receives several shocks, use the emergency plan agreed with the team.
- Tell every provider about the device before tests; ask the cardiologist before an MRI.

## Common mistakes

- Lifting the device-side arm above the shoulder to dress the patient in the first weeks.
- Not reporting persistent hiccups.
- Forgetting to give the device card and its explanation at discharge.
- Leaving the patient without a plan for what to do after an ICD shock.
- Not telling the imaging or surgical team that the patient has a device.

## Test yourself

Think of the answer, then tap the question to see it.

## Why is the arm on the device side kept below the shoulder in the first weeks?

To keep the new leads from moving out of place while they become fixed in the heart.

## Which symptoms after a pacemaker or ICD implant should be reported?

Wound redness, swelling, drainage or pain, dizziness, fainting, chest pain, breathlessness, persistent hiccups or the return of the old symptoms.

## What should a person with an ICD do after a shock?

Report every shock to the cardiology team; if they feel unwell, faint or get several shocks, follow the emergency plan agreed in advance.

## Which device precautions are taught at discharge?

Carry the device card, keep magnets and some power tools away, use the phone on the opposite side and show the card at security checks.

[Add to my cards (4)](https://durgical.app/estudiar/?add=/en/nursing/patients-with-a-pacemaker-or-icd-care-after-implant-wound-and-arm-care-device-te/)

## Connections

## Related 3

- [Cardiac monitoring at the bedside: leads, alarms and rhythm changes to report](https://durgical.com/en/nursing/cardiac-monitoring-at-the-bedside-leads-alarms-and-rhythm-changes-to-report/)
- [Recording a 12-lead ECG](https://durgical.com/en/nursing/recording-a-12-lead-ecg/)
- [Nursing care in atrial fibrillation: apical–radial pulse, stroke warning signs and teaching about anticoagulants](https://durgical.com/en/nursing/nursing-care-in-atrial-fibrillation-apical-radial-pulse-stroke-warning-signs-and/)

## Related conditions 3

- [Atrioventricular (heart) block](https://durgical.com/en/conditions/atrioventricular-block/)
- [Sinus node dysfunction (sick sinus syndrome) and symptomatic bradycardia](https://durgical.com/en/conditions/sinus-node-dysfunction-and-symptomatic-bradycardia/)
- [Ventricular tachycardia](https://durgical.com/en/conditions/ventricular-tachycardia/)

[← All of nursing](https://durgical.com/en/nursing/)

Educational content for students; it does not replace your institution's protocols, supervised clinical training or a prescriber's order. Dose-calculation examples use made-up numbers: they are educational, not a clinical order.

Sources: [Heart pacemaker - discharge: MedlinePlus Medical Encyclopedia](https://medlineplus.gov/ency/patientinstructions/000097.htm) (MedlinePlus, US National Library of Medicine, 2026); [Implantable cardioverter defibrillator - discharge: MedlinePlus Medical Encyclopedia](https://medlineplus.gov/ency/patientinstructions/000108.htm) (MedlinePlus, US National Library of Medicine, 2026); [Nursing Advanced Skills, 7.4 ECG Patterns and Dysrhythmias](https://med.libretexts.org/Bookshelves/Nursing/Nursing_Advanced_Skills_(OpenRN)/07%3A_Interpret_Basic_ECG/7.04%3A_ECG_Patterns_and_Dysrhythmias) (Open RN (Chippewa Valley Technical College), LibreTexts, 2023).

## **Spotted a mistake?** We are always improving for the community. Tell us what is wrong and our team will review it. Report a mistake

Representative model, for educational purposes only.

---
Source: https://durgical.com/en/nursing/patients-with-a-pacemaker-or-icd-care-after-implant-wound-and-arm-care-device-te/
License: CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/). Cite as: DurgiPedia (durgical.com), https://durgical.com/en/nursing/patients-with-a-pacemaker-or-icd-care-after-implant-wound-and-arm-care-device-te/
