Disinfecting surfaces, impressions and lab work
- Procedure
Surfaces touched during care are disinfected or covered between patients. Impressions and lab items are rinsed and disinfected before leaving the clinic.
What it is
Clinical contact surfaces (light handles, chair controls, trays, switches) are touched with gloved hands and splashed during treatment. They are either covered with disposable barriers changed between patients or cleaned and disinfected with a registered hospital disinfectant. Housekeeping surfaces (floors, walls) need routine cleaning. Impressions, bite records, prostheses and appliances carry saliva and blood and must be rinsed and disinfected with a product compatible with the material before they go to or come from the laboratory.
Indications and contraindications
- Clean first, then disinfect: organic matter inactivates many disinfectants.
- Follow the product's contact time; surfaces must stay wet for that time.
- Barriers suit hard-to-clean items such as switches and keyboards.
- Impressions: rinse under running water, disinfect by spray or immersion as the material allows, rinse again and label as disinfected.
- Prostheses returning from the lab are disinfected before they go into the patient's mouth.
How it is done
- Wear utility gloves and eye protection for cleaning.
- Remove barriers and visible soil.
- Apply the disinfectant and leave it for the stated contact time.
- Place new barriers where used.
- Rinse, disinfect and label impressions and lab items before dispatch.
| Category | Examples | What to do | How often |
|---|---|---|---|
| Clinical contact surface | Light handle, chair controls, tray, switches | Barrier, or clean then disinfect for the contact time | After every patient |
| Housekeeping surface | Floors, walls, sinks | Routine cleaning; disinfect when soiled with blood | On a schedule |
| Impressions and bite records | Alginate, elastomers, wax bites | Rinse, disinfect with a compatible product, rinse, label | Every item before the laboratory |
| Prostheses and appliances | Dentures, orthodontic appliances | Clean and disinfect | Before and after the laboratory |
Complications and pitfalls
- Some disinfectants distort alginate or damage acrylics: check compatibility.
- Mixing cleaning chemicals (for example bleach and ammonia) releases toxic gases.
- Laboratories should know which items arrive disinfected.
Next step / Initial management
- Write a cleaning and disinfection schedule for every room.
- Use a disinfectant compatible with each impression material and record that it was done.
- Staff skin or breathing reactions to disinfectants: review products and refer the worker to occupational health.
Common traps
- A quick wipe with disinfectant is enough: the surface must stay wet for the product's contact time
- Disinfectant works on a surface with visible blood: organic matter inactivates many disinfectants, so clean first
- Any disinfectant suits every impression: some distort alginate or damage acrylic, so check compatibility
- Mixing cleaning products makes them stronger: bleach with ammonia or acids releases toxic gases
Test yourself
Think of the answer, then tap the question to see it.
Why must surfaces be cleaned before disinfection?
Organic matter such as blood and saliva inactivates many disinfectants and shields microorganisms.
How are impressions handled before going to the laboratory?
Rinsed, disinfected with a compatible product for the required time, rinsed again and labelled as disinfected.
What is a clinical contact surface?
A surface touched or splashed during patient care, such as light handles, chair controls and trays.
A 50-year-old patient's alginate impression is bagged and sent to the laboratory straight from the mouth. What was missed?
Rinsing, disinfecting with a product compatible with alginate for the stated time, rinsing again and labelling it as disinfected.
A 29-year-old assistant develops a cough and itchy eyes after the clinic switches surface disinfectant. What is the next step?
Review the product and ventilation, consider a less irritating alternative, and refer the worker to occupational health.
Connections
Educational content; it does not replace assessment by a dentist or doctor and is not a clinical instruction. For facial or neck swelling with difficulty swallowing or breathing, a knocked-out tooth or bleeding that will not stop, go to an emergency department at once.
Sources: Disinfectants (StatPearls Publishing (NCBI Bookshelf), 2025); Dental Infection Control (StatPearls Publishing (NCBI Bookshelf), 2023); Dental Impression Materials (StatPearls Publishing (NCBI Bookshelf), 2023); Best Practices for Environmental Infection Prevention and Control (Centers for Disease Control and Prevention, 2024); Guidelines for Infection Control in Dental Health-Care Settings — 2003 (Centers for Disease Control and Prevention (MMWR), 2003); Chemical Disinfectants: Guideline for Disinfection and Sterilization in Healthcare Facilities (Centers for Disease Control and Prevention, 2024); 6 Steps for Safe & Effective Disinfectant Use (U.S. Environmental Protection Agency, 2020).
Spotted a mistake?We are always improving for the community. Tell us what is wrong and our team will review it.Report a mistake