Durgical
EN
Open the app

Risk-of-bias tools: RoB 2, ROBINS-I, Newcastle-Ottawa, QUADAS-2, AMSTAR 2

  • Concept

A systematic review is only as trustworthy as the studies it pools. Risk-of-bias tools are the structured way to ask whether each result can be believed.

Updated

What it is

Risk-of-bias tools judge whether flaws in a study's design or conduct are likely to have pushed its result away from the truth. The tool depends on the design: RoB 2 for randomised trials, ROBINS-I for non-randomised studies of interventions, the Newcastle-Ottawa scale for cohort and case-control studies, QUADAS-2 for diagnostic accuracy studies, and AMSTAR 2 or ROBIS for systematic reviews. Each is organised into domains judged one by one. They judge how a study was done, unlike reporting guidelines, which judge what a paper tells you.

Key facts

  • ROBINS-I domains: confounding, selection of participants, classification of interventions, deviations, missing data, outcome measurement, selection of the reported result.
  • ROBINS-E is the version for non-randomised studies of exposures (environment, behaviour).
  • QUADAS-2 domains: patient selection, index test, reference standard, flow and timing; it also rates applicability.
  • Domain-based judgements are preferred to summed quality scores, which add unrelated items and hide the one fatal flaw.
  • Risk of bias differs from imprecision: a small trial may be unbiased but uncertain.

Worked example

  1. Made-up review: early mobilisation after abdominal surgery and pneumonia; 10 studies: 6 randomised trials and 4 cohort studies.
  2. Trials, RoB 2 for the pneumonia result: 3 low risk, 2 some concerns, 1 high.
  3. The high-risk trial is low in 4 domains but its allocation was not concealed: the worst domain sets the overall rating.
  4. Cohorts, ROBINS-I against a target trial: 1 moderate, 2 serious, 1 critical (the sicker patients stayed in bed: confounding).
  5. Meta-analysis of all 6 trials: RR 0.70. Sensitivity analysis without the high-risk trial: RR 0.82.
  6. Reading: the benefit shrinks without the biased trial; the review reports both and lowers its GRADE certainty for risk of bias.

Which tool for which design

ToolDesign judgedWhat it looks atRating
RoB 2Randomised trial (variants for cluster and crossover)5 domains, from randomisation to selective reportingLow, some concerns, high
ROBINS-INon-randomised study of an intervention7 domains, compared with a target trialLow, moderate, serious, critical
Newcastle-OttawaCohort or case-controlSelection, comparability, outcome or exposureStars per domain
QUADAS-2Diagnostic accuracy studyPatient selection, index test, reference standard, flow and timingRisk of bias and applicability: low, high, unclear
AMSTAR 2 / ROBISSystematic reviewProtocol, search, selection, risk-of-bias handling, synthesisOverall confidence or risk of bias of the review

Markers

  • RoB 2
  • ROBINS-I
  • NOS
  • QUADAS-2
  • AMSTAR 2
  • ROBIS

In practice

  • Before acting on a pooled result, check how many of its studies are at high risk and whether removing them changes the answer.
  • Two reviewers rate risk of bias independently and resolve disagreements; the judgement and its reason are shown in a table or traffic-light plot.

Common traps

  • A trial that follows CONSORT is at low risk of bias: CONSORT checks that the methods are reported; a well-reported trial can still be badly run
  • One overall rating per study is enough: RoB 2 rates each result; an unblinded trial may be at low risk for death and high risk for pain
  • A high total quality score means a trustworthy study: summed scores let good items hide a fatal flaw; the worst domain matters
  • Small trials are biased: small size causes imprecision (wide CI), not bias; risk of bias concerns systematic error
  • RoB 2 can be used for cohort studies: non-randomised studies of interventions need ROBINS-I, which starts from confounding

Test yourself

Think of the answer, then tap the question to see it.

A review pools 8 randomised trials and 5 cohort studies of the same treatment. Which risk-of-bias tools fit each design?

RoB 2 for the randomised trials and ROBINS-I for the cohort studies (the Newcastle-Ottawa scale is an older alternative for cohorts).

A trial is rated low risk in four RoB 2 domains and high risk in missing outcome data. What is its overall rating, and why?

High: the overall judgement follows the least favourable domain, because one serious flaw can bias the result whatever the other domains show.

How do risk-of-bias tools differ from reporting guidelines such as STROBE?

Reporting guidelines list what a paper should describe; risk-of-bias tools judge whether the way the study was done is likely to have distorted its result.

Why might one trial get different RoB 2 ratings for two outcomes?

Ratings are per result: without blinding, a subjective outcome such as pain is at higher risk of biased measurement than all-cause death.

Add to my cards (4)

Connections

← All of epidemiology

Educational content on epidemiological and statistical methods; the examples use made-up numbers to teach the calculation. Not a clinical or legal guide: current Colombian rules are in the official sources.

Sources: Chapter 8: Assessing risk of bias in a randomized trial (Cochrane, 2024); Chapter 25: Assessing risk of bias in a non-randomized study (Cochrane, 2024); Risk of bias tools (riskofbias.info, 2026); The Newcastle-Ottawa Scale (NOS) for assessing the quality of nonrandomised studies in meta-analyses (Ottawa Hospital Research Institute, 2026).

Spotted a mistake?We are always improving for the community. Tell us what is wrong and our team will review it.Report a mistake

Representative model, for educational purposes only.