Reading the fetal heart trace (CTG) in labour
- Approach to a problem
The fetal heart trace is the baby's only way to tell you it is running out of oxygen. Read it the same way every time and you will not miss the warning.
What it is
Cardiotocography (CTG) records the fetal heart rate together with uterine contractions. It is read systematically: contractions, baseline rate, variability, accelerations and decelerations, then classified (for example, FIGO's normal, suspicious and pathological) and acted on. A normal trace is very reassuring; an abnormal trace is often a false alarm, so it prompts correction of reversible causes and, if it persists, further assessment or birth. Intermittent auscultation is the recommended method for healthy women in spontaneous labour.
Red flags
- Late decelerations that recur with most contractions, especially with reduced variability.
- Variability under 5 beats per minute for a long period, or a flat trace.
- A prolonged deceleration lasting more than a few minutes, or bradycardia.
- A sinusoidal pattern: smooth regular waves suggesting fetal anaemia (for example, vasa praevia bleeding or Rh disease).
- Fetal tachycardia with maternal fever: chorioamnionitis until shown otherwise.
Step-by-step approach
- Check the context: gestational age, risk factors, oxytocin, analgesia, maternal temperature and pulse (and make sure you are not recording the mother's heart).
- Contractions: count them over 10 minutes; more than 5 averaged over 30 minutes is tachysystole.
- Baseline: the mean rate between contractions over about 10 minutes; normal 110 to 160 beats per minute.
- Variability: the band width of the baseline; normal 5 to 25 beats per minute.
- Accelerations: rises of at least 15 beats for 15 seconds are reassuring.
- Decelerations: classify by timing and shape (early, variable, late, prolonged) and count how many contractions they follow.
- Classify the trace; correct causes first (position, fluids, stop oxytocin, treat low pressure or fever), reassess, and expedite birth if still pathological.
The three decelerations
| Type | Shape and timing | What is squeezed | Meaning |
|---|---|---|---|
| Early | Gradual, mirrors the contraction, lowest point at its peak | The fetal head | Benign; no action |
| Variable | Abrupt drop and recovery, varying shape, not tied to the contraction | The umbilical cord | Usually tolerated; worrying if deep, long or with lost variability |
| Late | Gradual, starts after the contraction begins, lowest point after its peak | The placenta (reduced uteroplacental flow) | Fetal hypoxia; act at once if recurrent |
| Prolonged | Drop lasting more than about 3 minutes | Any cause: tachysystole, hypotension, cord prolapse, abruption, rupture | Emergency if it does not recover |
Keys to the differential
- A recent epidural causing maternal hypotension is a common, reversible cause of a deceleration: fix the blood pressure first.
- Tachysystole from oxytocin starves the placenta between contractions; stopping the infusion is often the whole treatment.
- A sudden prolonged bradycardia with pain and loss of station in a woman with a uterine scar suggests uterine rupture.
- How a healthy fetus copes with labour: each contraction squeezes the spiral arteries of the placental bed and sometimes the cord → oxygen dips with every contraction → decelerations lower the heart's workload, accelerations stop as non-essential movement stops, catecholamines raise the baseline, and blood is redirected to the heart, brain and adrenals → most fetuses stay compensated. Fetal haemoglobin, which holds oxygen at low pressures, adds reserve. A fetus already compromised (growth restriction, infection, anaemia) has less reserve and can decompensate fast.
- Fetal scalp blood sampling: a small sample of fetal scalp blood for pH when the trace is abnormal. It may avoid some caesareans, but it is invasive, gives one moment rather than a trend and can fail for lack of blood; its use is falling, and it is kept for selected cases.
- Fetal scalp stimulation: an acceleration in response to stimulating the scalp may reassure that labour can continue; trials are small and the evidence very uncertain.
- Fetal pulse oximetry: a sensor reads fetal oxygen saturation; values under 30% were linked with low cord pH, low Apgar scores and neonatal intensive care, and adding it to the trace was associated with fewer caesareans for suspected distress without worse short-term outcomes. It is not widely available.
- ST analysis of the fetal ECG: needs a scalp electrode after the membranes have ruptured; compared with the trace alone it made no clear difference to caesareans, metabolic acidosis or encephalopathy, with slightly fewer scalp samples and assisted vaginal births.
- Meconium-stained amniotic fluid: uncommon before 37 weeks (about 2%) and common after 42 weeks (up to 44%). It matters most with an abnormal trace, when neonatal hypoxia is much more likely; thick meconium, an abnormal trace and a low Apgar score raise the risk of meconium aspiration syndrome.
Next step / Initial management
- Intrauterine resuscitation: turn her onto her side, stop oxytocin, give intravenous fluids, correct hypotension, treat fever and consider a tocolytic for tachysystole.
- If the trace stays pathological despite correction, obtain senior review and expedite birth by the fastest safe route.
- Refer or transfer early when continuous monitoring or emergency caesarean is not available where she is.
- Keep the trace and document the classification and every action.
- With meconium-stained fluid: watch the trace closely and have someone skilled in newborn resuscitation at the birth. Routine amnioinfusion is not recommended, suctioning at the perineum does not prevent aspiration, and current newborn resuscitation favours ventilating a non-vigorous baby over routine tracheal suction.
Common traps
- Recording the mother's pulse instead of the fetal heart: always compare with the maternal pulse, especially in the second stage.
- Reading a trace without counting contractions: tachysystole is a common, fixable cause.
- Calling every deceleration 'late': timing relative to the contraction peak is what separates head compression from placental insufficiency.
- Being falsely reassured by a normal baseline rate: loss of variability with late decelerations is pathological even at 140 beats per minute.
- Meconium in the fluid means fetal distress: meconium passage is common at term and beyond; it is the combination with an abnormal trace, or thick meconium, that signals danger.
Test yourself
Think of the answer, then tap the question to see it.
Why do late decelerations start after the contraction begins?
Each contraction cuts uteroplacental blood flow; a fetus with little reserve becomes hypoxic only after a delay, so the heart rate falls late and recovers after the contraction ends.
A trace shows deep decelerations after starting oxytocin, with 7 contractions in 10 minutes. What is the first step?
Stop the oxytocin (tachysystole), turn the woman onto her side and give fluids, then reassess the trace.
What does a smooth, regular sine-wave pattern suggest?
Fetal anaemia, for example from vasa praevia bleeding or red cell alloimmunisation; it needs urgent assessment.
Elsewhere in DurgiPedia
- Fetal heart monitoring in labour: intermittent auscultation, CTG in general terms and intrauterine resuscitation
- Fetal circulation and the transition at birth
Connections
← All of obstetrics and gynaecology
Educational content; it does not replace assessment by a doctor or your institution's protocols, and it contains no doses. For heavy bleeding, a severe headache or blurred vision, a seizure, fever, strong abdominal pain or fewer baby movements, go to an emergency department at once.
Sources: Fetal Heart Rate Tracing: Assessment and Clinical Interpretation (StatPearls Publishing (NCBI Bookshelf), 2026); Antenatal Fetal Surveillance (StatPearls Publishing (NCBI Bookshelf), 2024); WHO recommendations: intrapartum care for a positive childbirth experience (World Health Organization, 2018); Pathophysiological interpretation of fetal heart rate tracings in clinical practice (American Journal of Obstetrics and Gynecology, PubMed 37270259, 2023); Implementation of physiological interpretation of fetal heart rate changes: from scientific principles to frontline practice (Journal of Maternal-Fetal & Neonatal Medicine, PubMed 41535023, 2026); Should fetal blood sampling still be a part of monitoring during labor in the modern era? (Journal of Gynecology Obstetrics and Human Reproduction (Garabedian C, Girault A), PubMed 40581336, 2025); Fetal scalp stimulation for assessing fetal well-being during labour (Cochrane review) (Cochrane Database of Systematic Reviews (Murphy DJ et al.), 2023); Association between intrapartum fetal pulse oximetry and adverse perinatal and long-term outcomes: A systematic review and meta-analysis (International Journal of Gynecology & Obstetrics (Mitchell JM et al.), 2025); Fetal electrocardiogram (ECG) for fetal monitoring during labour (Cochrane review) (Cochrane Database of Systematic Reviews (Neilson JP), 2015); Neonatal Respiratory Distress Secondary to Meconium Aspiration Syndrome (Children (Basel), 2021); Approach to Infants Born Through Meconium Stained Amniotic Fluid: Evolution Based on Evidence? (American Journal of Perinatology, PubMed 29341045, 2018).
Spotted a mistake?We are always improving for the community. Tell us what is wrong and our team will review it.Report a mistake
Representative model, for educational purposes only.